COMPONENT INSTALLATION
Installation of the Condensing Unit
Materials Required
●6 Stainless steel or bronze wood screws
Tools Required
●Marking pencil
●Tape measure
●1/8" Allen key (or hex wrench) for the retaining screws
●Screw driver
●Heat gun, lighter, or propane torch
The condensing unit is comprised of two separate pieces - the main unit and the mounting base,
that are joined together with screws. To minimize the transmission of vibration, the main unit is
not rigidly mounted to the base. Instead, it rests on rubber bumpers which are part of the
mounting base. Four (4) retaining screws are used to prevent the main unit from substantially
separating from the mounting base in the event of a capsize or similar severe angle or jarring.
The retaining screws are not intended to tightly secure the main unit and base. They are simply
there to prevent extreme movement.
To mount your condensing unit:
1. Remove the 4 retaining screws and allow the mounting base to separate from the main unit.
2. Using 6 wood screws or bolts to secure the mounting base in the selected location.
3. Set the main unit onto the base and replace the 4 retaining screws.